Your water jetter is a serious investment, and like any engine-driven machine, it needs regular care to stay reliable. A missed service can lead to low pressure, breakdowns on site and costly repairs.
Here’s the recommended service schedule and pre-start routine from the Enviroline Sewerjett operator’s manual.
Why servicing matters
Regular servicing keeps your jetter performing at full pressure and helps catch worn parts before they fail. It also protects your warranty. To keep warranty coverage, your jetter must be operated and maintained in line with the operator’s manual, using genuine Enviroline parts.
Sewerjett service schedule
Service your jetter at whichever comes first, the engine hours or the time interval:
| Service | Interval |
|---|---|
| First service | 50 hours or 6 months |
| Second service | 150 hours or 12 months |
| Third service | 250 hours or 18 months |
| Fourth service | 350 hours or 24 months |
Each service includes changing the spark plugs, oil filter, fuel filter and air filter (where applicable). Record the date and engine hours in your service log at every service.
All servicing and repairs should be carried out by an approved Sewerjett repair agent.
Pre-start checks before every job
Before each use, run through these checks:
- Check and clean the water filters.
- Check all oil levels and oil quality. If the pump oil looks milky, change it immediately.
- Check guards, shields and safety valves.
- Inspect all valves, fittings and hoses for wear or corrosion. Never use a hose with exposed braiding.
- Confirm a good clean water supply. Recycled water isn’t suitable for jetting equipment.
If you find a fault, tag the machine with a “Defective” or “Do Not Use” tag and report it before anyone operates it.
Use the right oils and fuel
Using the correct fluids protects your engine, pump and gearbox. For Sewerjett VS2, VS3 and Hornet 40HP EFI models:
- Engine oil: 10W30
- Pump oil: 15W40
- Gearbox oil: 80W90
- Fuel: 95 RON or higher
Always check your model’s specifications in the operator’s manual.
After every job
- Drain the water tank after jetting and before travel. Leaving water in the tank can damage the float valve and cause overflows that damage your machine or vehicle.
- Depressurise the system fully before disconnecting any hose or fitting.
- Clean and inspect your hose before rewinding it.
Book your next jetter service with Enviroline
Enviroline services Sewerjett water jetters and supplies genuine parts, nozzles and replacement jetter hose. Keep your machine on the road and your warranty intact.
Contact our team to book a service, or browse our pipe maintenance range.